Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Circ Arrhythm Electrophysiol ; 17(2): e012377, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38288627

RESUMO

BACKGROUND: The incidence and prognosis of right bundle branch block (RBBB) following transcatheter aortic valve replacement (TAVR) are unknown. Hence, we sought to characterize the incidence of post-TAVR RBBB and determine associated risks of permanent pacemaker (PPM) implantation and mortality. METHODS: All patients 18 years and above without preexisting RBBB or PPM who underwent TAVR at US Mayo Clinic sites and Mayo Clinic Health Systems from June 2010 to May 2021 were evaluated. Post-TAVR RBBB was defined as new-onset RBBB in the postimplantation period. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. RESULTS: Of 1992 patients, 15 (0.75%) experienced new RBBB post-TAVR. There was a higher degree of valve oversizing among patients with new RBBB post-TAVR versus those without (17.9% versus 10.0%; P=0.034). Ten patients (66.7%) with post-TAVR RBBB experienced high-grade atrioventricular block and underwent PPM implantation (median 1 day; Q1, 0.2 and Q3, 4), compared with 268/1977 (13.6%) without RBBB. Following propensity score adjustment for covariates (age, sex, balloon-expandable valve, annulus diameter, and valve oversizing), post-TAVR RBBB was significantly associated with PPM implantation (hazard ratio, 8.36 [95% CI, 4.19-16.7]; P<0.001). No statistically significant increase in mortality was seen with post-TAVR RBBB (hazard ratio, 0.83 [95% CI, 0.33-2.11]; P=0.69), adjusting for age and sex. CONCLUSIONS: Although infrequent, post-TAVR RBBB was associated with elevated PPM implantation risk. The mechanisms for its development and its clinical prognosis require further study.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Estenose da Valva Aórtica/cirurgia , Incidência , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
2.
Clin Anat ; 37(1): 43-53, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37337379

RESUMO

Outflow tract ventricular arrhythmias are the most common type of idiopathic ventricular arrhythmia. A systematic understanding of the outflow tract anatomy improves procedural efficacy and enables electrophysiologists to anticipate and prevent complications. This review emphasizes the three-dimensional spatial relationships between the ventricular outflow tracts using seven anatomical principles. In turn, each principle is elaborated on from a clinical perspective relevant for the practicing electrophysiologist. The developmental anatomy of the outflow tracts is also discussed and reinforced with a clinical case.


Assuntos
Arritmias Cardíacas , Ablação por Cateter , Humanos , Ventrículos do Coração , Eletrofisiologia , Ablação por Cateter/métodos , Eletrocardiografia/métodos
4.
Circ Arrhythm Electrophysiol ; 16(8): 437-446, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37485717

RESUMO

BACKGROUND: The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described. METHODS: In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use. RESULTS: One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14-69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non-pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%-45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00-1.06] per 1 mL/m2 increment; P=0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21-0.90]; P=0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8-37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs. CONCLUSIONS: Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Veias Pulmonares , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
5.
Front Cardiovasc Med ; 10: 1143409, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37273874

RESUMO

A 70-year-old female presented with incessant supraventricular tachycardia that was refractory to metoprolol and sotalol. ECG revealed a narrow complex tachycardia with a rate of 163 beats per minute with a short RP relationship. She had salvos of atrial tachycardia which led to a severe reduction in ejection fraction as noted on echocardiography and hemodynamic instability. An electrophysiological study was performed, and findings suggested this to be an atrial tachycardia with earliest activation in the perinodal area. Radiofrequency ablation was carried out along the septum and associated structures to surround this region including the right atrium, non-coronary sinus of Valsalva, and the left atrium (anterior wall outside of the right superior pulmonary vein) to isolate this area and surround the focus with ablation lesions. The patient has done well post-procedure and continues to do well without any recurrence on low-dose flecainide at 8 months.

7.
JACC CardioOncol ; 5(2): 203-212, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37144110

RESUMO

Background: The prevention of stroke in patients with atrial fibrillation (AF) and cancer is challenging because patients are at increased bleeding and thrombotic risk. Objectives: The authors sought to assess left atrial appendage occlusion (LAAO) as a safe and effective strategy for reducing stroke at no increased bleeding risk in cancer patients with AF. Methods: We reviewed patients with nonvalvular AF who underwent LAAO at Mayo Clinic sites from 2017 to 2020 and identified those who had undergone prior or current treatment for cancer. We compared the incidence of stroke, bleeding, device complications, and death with a control group who underwent LAAO without malignancy. Results: Fifty-five patients were included; 44 (80.0%) were male, and the mean age was 79.0 ± 6.1 years. The median CHA2Ds2-VASc score was 5 (Q1-Q3: 4-6), with 47 (85.5%) having a prior bleeding event. Over the first year, ischemic stroke occurred in 1 (1.4%) patient, bleeding complications in 5 (10.7%) patients, and death in 3 (6.5%) patients. Compared with controls who underwent LAAO without cancer, there was no significant difference in ischemic stroke (HR: 0.44; 95% CI: 0.10-1.97; P = 0.28), bleeding complication (HR: 0.71; 95% CI: 0.28-1.86; P = 0.19), or death (HR: 1.39; 95% CI: 0.73-2.64; P = 0.32). Conclusions: Within our cohort, LAAO in cancer patients was achieved with good procedural success and offered a reduction in stroke at no increased bleeding risk similar to noncancer patients.

9.
Am J Cardiol ; 186: 203-208, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36328832

RESUMO

The co-morbidities and long-term complications of spontaneous coronary artery dissection (SCAD) are incompletely understood. This study investigated the association of atrial arrhythmias (AA), defined as atrial fibrillation and atrial flutter, with SCAD in a patient registry and population-based cohort. This observational study was performed in 2 parts. The first was a retrospective study reviewing patients diagnosed with AA in the Mayo Clinic SCAD Registry. The second was a population-based, case-control study to assess AA in patients with SCAD compared with age- and gender-matched controls. Of 1,214 patients in the Mayo Clinic SCAD Registry, 45 patients (3.7%) with SCAD were identified with an AA. A total of 8 of those patients (17.8%) had a pre-SCAD AA; 20 (44.4%) had a peri-SCAD AA; and 17 (37.8%) had a post-SCAD AA. The univariate analysis did not reveal significant associations with traditional cardiovascular risk factors. In the population-based cohort, 5 patients with SCAD (4%) and 4 controls (1%) developed an AA before the date of SCAD for each patient (odds ratio 4.5, 95% confidence interval [CI] 1.05 to 19.0, p = 0.04). A total of 5 patients with SCAD (4%) and 3 controls (1%) developed an AA in the 10 years after SCAD (hazard ratio 6.3, 95% CI 1.2 to 32.8, p = 0.03). A subgroup of patients with SCAD experienced AA before and after SCAD. Patients with a history of SCAD were more likely to develop AA in the next 10 years than were age- and gender-matched healthy controls.


Assuntos
Anomalias dos Vasos Coronários , Doenças Vasculares , Humanos , Vasos Coronários , Estudos Retrospectivos , Estudos de Casos e Controles , Angiografia Coronária , Fatores de Risco , Fatores de Tempo , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/epidemiologia , Doenças Vasculares/complicações , Doenças Vasculares/epidemiologia , Doenças Vasculares/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações
10.
J Cardiovasc Electrophysiol ; 34(1): 229-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946395

RESUMO

A 70-year-old woman with longstanding persistent atrial fibrillation underwent Micra leadless pacemaker implantation and atrioventricular nodal ablation. No postprocedural complications were noted. She subsequently underwent surgical mitral valve replacement 4 years later. During the surgery, Micra tine perforation of the right ventricular free wall was seen. No device revision was performed due to her asymptomatic status and stable pacemaker position/function. Pericardial effusion is a known complication of Micra implantation. The incidence of tine perforation is unknown as many patients may be asymptomatic. The clinical consequences regarding adverse events, device functionality, and explantation/extraction risk profile remain to be determined.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Humanos , Feminino , Idoso , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Nó Atrioventricular
13.
Front Cardiovasc Med ; 10: 1328898, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38169814

RESUMO

Background: Pathogenic/Likely pathogenic variants in DSP-encoded desmoplakin are strongly associated with arrhythmogenic cardiomyopathy (ACM). However, their contribution towards sinus node dysfunction has not been well-delineated. Case summary: A 74-year-old man with a pathogenic variant of DSP-encoded desmoplakin (c.478C >T; p.Arg160X) but no evidence of ACM presented with one episode of syncope in the setting of a gastrointestinal illness. Workup including echocardiography, cardiac magnetic resonance imaging, and Holter monitor did not show evidence of ACM or significant arrhythmias. One month later, he experienced several closely-spaced episodes of syncope associated with long sinus pauses and sinus arrest documented on telemetry. He underwent urgent dual chamber pacemaker implantation, during which a ventricular programmed stimulation study was performed and was negative for sustained ventricular arrhythmias. His syncopal episodes resolved and he had no recurrent events on three-month follow-up. Discussion: As highlighted here, DSP-encoded desmoplakin pathogenic/Likely pathogenic variants may contribute to isolated sinus node dysfunction. This clinical link should be further explored in larger studies involving patients with DSP variants.

14.
JACC Clin Electrophysiol ; 8(9): 1106-1118, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36137715

RESUMO

BACKGROUND: Pulsed electric field (PEF) ablation is an emerging modality for the treatment of cardiac arrhythmias. Data regarding effects on the interventricular septum are limited, and the optimal delivery protocol and electrode configuration remain undefined. OBJECTIVES: This study sought to evaluate the electrophysiological, imaging, and histological characteristics of bipolar direct-current PEF delivered across the interventricular septum. METHODS: PEF was applied between identical solid-tip ablation catheters positioned on either side of the septum in a chronic canine model. Intracardiac and surface electrophysiological data were recorded following delivery. In 4 animals, cardiac magnetic resonance (CMR) was performed early (6 ± 2 days) and late (30 ± 2 days) postablation. After 4 weeks of survival, cardiac specimens were sectioned for histopathological analysis. RESULTS: In 8 canines, PEF was delivered in 27 separate septal sites (45 ± 17 J/site) with either microsecond or nanosecond PEF. Acute complications included transient complete atrioventricular block in 5 animals (63%) after delivery at the anterobasal septum, with right bundle branch block persisting in 3 (38%). Ventricular fibrillation occurred in 1 animal during microsecond but not nanosecond PEF. Postprocedural CMR showed prominent edema and significant left ventricular systolic dysfunction, which recovered with late imaging. At 4 weeks, 36 individual well-demarcated lesions were demonstrated by CMR and histopathology. Lesion depth measured by histology was 2.6 ± 2.1 mm (maximum 10.9 mm and near transmural). CONCLUSIONS: Bipolar PEF ablation of the interventricular septum is feasible and can produce near transmural lesions. Myocardial stunning, edema, and conduction system injury may occur transiently. Further studies are required to optimize safe delivery and efficacious lesions.


Assuntos
Ablação por Cateter , Septo Interventricular , Animais , Bloqueio de Ramo , Ablação por Cateter/métodos , Cães , Eletroporação , Sistema de Condução Cardíaco , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia
15.
Artigo em Inglês | MEDLINE | ID: mdl-35948726

RESUMO

BACKGROUND: While the triggers for ventricular fibrillation (VF) are well-known, the substrate required for its maintenance remains elusive. We have previously demonstrated dynamic spatiotemporal changes across VF from electrical induction of VF to asystole. Those data suggested that VF drivers seemed to reside in the distal RV and LV. However, signals from these areas were not recorded continuously. The aim of this study was to map these regions of significance with stationary basket electrodes from induction to asystole to provide further insights into the critical substrate for VF rhythm sustenance in canines. METHODS: In six healthy canines, three multipolar basket catheters were positioned in the distal right ventricle (RV), RV outflow tract, and distal left ventricle (LV), and remained in place throughout the study. VF was induced via direct current application from an electrophysiologic catheter. Surface and intracardiac electrograms were recorded simultaneously and continuously from baseline, throughout VF, and until asystole, in order to get a complete electrophysiologic analysis of VF. Focused data analysis was also performed via two defined stages of VF: early VF (immediately after induction of VF to 10 min) and late VF (after 10 min up to VF termination and asystole). RESULTS: VF was continuously mapped for a mean duration of 54 ± 9 min (range 42-70 min). Immediately after initiation of VF in the early phase, the distal LV region appeared to drive the maintenance of VF. Towards the terminal stage of VF, the distal RV region appeared to be responsible for VF persistence. In all canines, we noted local termination of VF in the LV, while VF on surface ECG continued; conversely, subsequent spontaneous termination of VF in the RV was associated with termination of VF on surface ECG into a ventricular escape rhythm. Continuous mapping of VF showed trends towards an increase in peak-to-peak ventricular electrogram cycle length (p = 0.06) and a decrease in the ventricular electrogram amplitude (p = 0.06) after 40 min. Once we could no longer discern surface QRS activity, we demonstrated local ventricular myocardial capture in both the RV and LV but could not reinitiate sustained VF despite aggressive ventricular burst pacing. CONCLUSIONS: This study describes the evolution of VF from electrical initiation to spontaneous VF termination without hemodynamic support in healthy canines. These data are hypothesis-generating and suggest that critical substrate for VF maintenance may reside in both the distal RV and LV depending on stage of VF. Further studies are needed to replicate these findings with hemodynamic support and to translate such findings into clinical practice. Ventricular fibrillation maintenance may be dependent on critical structures in the distal RV. ECG: electrocardiogram; LV: left ventricle; RV: right ventricle; RVOT: right ventricular outflow tract; VF: ventricular fibrillation.

16.
Curr Probl Cardiol ; 47(11): 101335, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35872052

RESUMO

In the pivotal WATCHMAN trials, warfarin was used for post-procedural anticoagulation in the first 45 days after left atrial appendage closure. We aimed to investigate the efficacy and safety of direct oral anticoagulant (DOAC) versus warfarin after WATCHMAN. We performed a literature search of 5 electronic databases to identify studies comparing DOAC with warfarin after WATCHMAN. We pooled outcomes for the efficacy (thromboembolism, device-related thrombus [DRT], peridevice leak [PDL] >5 mm) and safety endpoints (bleeding, mortality). Thromboembolism was defined as ischemic stroke, transient ischemic attack, or systemic embolism. We included 10 cohort studies with 2,440 patients, of whom 1,397 (57.3%) received DOAC. Concerning periprocedural outcomes (within 7 days following implantation), DOAC was associated with a reduction in major bleeding (Risk ratio [RR] 0.32; 95% confidence interval [CI] 0.11-0.92) compared with warfarin, without significant differences in all bleeding (RR 0.46; 95% CI 0.15-1.42) and thromboembolism (RR 0.93; 95% CI 0.21-4.16). On first follow-up transesophageal echocardiography, DRT (RR 0.79; 95% CI 0.39-1.60) and PDL>5 mm (RR 0.44; 95% CI 0.16-1.20) were comparable among groups. With a mean follow-up of 1.5-12 months, DOAC was associated with reductions in major bleeding (RR 0.52; 95% CI 0.30-0.89) and all bleeding (RR 0.38; 95% CI 0.25-0.58) compared with warfarin. The outcomes of thromboembolism (RR 0.79; 95% CI 0.36-1.73) and all-cause mortality (RR 0.49; 95% CI 0.19-1.28) were not significantly different between the 2 groups. Following WATCHMAN implantation, DOAC was associated with reductions in major bleeding and all bleeding compared with warfarin at mid-term follow-up. The outcomes of thromboembolism, all-cause mortality, DRT, and PDL >5 mm were comparable among groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Trombose , Administração Oral , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Trombose/tratamento farmacológico , Resultado do Tratamento , Varfarina/efeitos adversos
17.
Artigo em Inglês | MEDLINE | ID: mdl-35771400

RESUMO

BACKGROUND: Mid-myocardial ventricular arrhythmias are challenging to treat. Cardiac electroporation via pulsed electric fields (PEFs) offers significant promise. We therefore tested PEF delivery using screw-in pacemaker leads as proof-of-concept. METHODS: In 5 canine models, we applied nanosecond PEF (pulse width 300 ns) across the right ventricular (RV) septum using a single lead bipolar configuration (n = 2) and between two leads (n = 3). We recorded electrograms (EGMs) prior to, immediately post, and 5 min after PEF. Cardiac magnetic resonance imaging (cMRI) and histopathology were performed at 2 weeks and 1 month. RESULTS: Nanosecond PEF induced minimal extracardiac stimulation and frequent ventricular ectopy that terminated post-treatment; no canines died with PEF delivery. With 1 lead, energy delivery ranged from 0.64 to 7.28 J. Transient ST elevations were seen post-PEF. No myocardial delayed enhancement (MDE) was seen on cMRI. No lesions were noted on the RV septum at autopsy. With 2 leads, energy delivery ranged from 56.3 to 144.9 J. Persistent ST elevations and marked EGM amplitude decreases developed post-PEF. MDE was seen along the septum 2 weeks and 1 month post-PEF. There were discrete fibrotic lesions along the septum; pathology revealed dense connective tissue with < 5% residual cardiomyocytes. CONCLUSIONS: Ventricular electroporation is feasible and safe with an active fixation device. Reversible changes were seen with lower energy PEF delivery, whereas durable lesions were created at higher energies. Central illustration: pulsed electric field delivery into ventricular myocardium with active fixation leads.

18.
Circ Arrhythm Electrophysiol ; 15(7): e010744, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35763435

RESUMO

BACKGROUND: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. METHODS: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. RESULTS: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P=0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. CONCLUSIONS: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.


Assuntos
Desfibriladores Implantáveis , Anomalia de Ebstein , Marca-Passo Artificial , Adulto , Desfibriladores Implantáveis/efeitos adversos , Anomalia de Ebstein/etiologia , Anomalia de Ebstein/cirurgia , Eletrônica , Feminino , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
J Am Heart Assoc ; 11(1): e023377, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34935408

RESUMO

Background The epidemiology of ventricular arrhythmias (VAs) in patients with advanced heart failure (HF) is not well defined. Methods and Results Residents of Olmsted County, Minnesota, with advanced HF from 2007 to 2017 were identified using the 2018 European Society of Cardiology criteria. Billing codes were used to capture VAs; severe VAs requiring emergency care were defined as events associated with emergency department visits or hospitalizations. The cumulative incidence of VAs postadvanced HF was estimated with the Kaplan-Meier method. Multivariable Cox analyses were used to determine the following: (1) Predictors of severe VAs postadvanced HF; and (2) Impact of severe VAs on mortality. Of 936 patients with advanced HF, 261 (27.9%) had a history of VA. The 1-year cumulative incidence of severe VAs postadvanced HF was 5.4%. Prior VAs (hazard ratio [HR] 2.22 [95% CI, 1.26-3.89], P=0.006) and left ventricular ejection fraction <40% (HR, 3.79 [95% CI, 1.72-8.39], P<0.001) were independently associated with increased severe VA risk postadvanced HF. New-onset severe VAs were associated with increased mortality (HR, 4.41 [95% CI, 2.80-6.94]; P<0.001), whereas severe VAs in patients with prior VAs had no significant association with mortality risk (HR, 1.08 [95% CI, 0.65-1.78]; P=0.77). Severe VAs were associated with increased mortality in patients without implantable cardioverter defibrillators (HR, 4.89 [95% CI, 2.89-8.26]; P<0.001), but not in patients with implantable cardioverter defibrillators (HR, 1.42 [95% CI, 0.92-2.19]; P=0.11). Conclusions Patients with left ventricular ejection fraction <40% and prior VAs have increased risk of severe VA postadvanced HF. New-onset severe VAs or severe VAs without implantable cardioverter defibrillators postadvanced HF are associated with increased mortality.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA